Ignore:
Timestamp:
08/23/14 02:43:01 (6 years ago)
Author:
Antoine Martin
Comment:

Sorry about that, r7420 should fix this. (r7421 is also worth having)

Does that work for you?

Will backport both to v0.14.x and make a new release.

Legend:

Unmodified
Added
Removed
Modified
  • Ticket #658

    • Property Owner changed from Antoine Martin to sschnitzer
    • Property Priority changed from major to critical
  • Ticket #658 – Description

    initial v1  
    1212}}}
    1313
    14 From what I got until now, the server fails in xpra/net/protocol.py in the line "if read_buffer[0] not in ("P", ord("P")):"
     14From what I got until now, the server fails in {{{xpra/net/protocol.py}}} in the line "{{{if read_buffer[0] not in ("P", ord("P")):}}}"
    1515If a client connects directly (i.e., without proxy), a prefix of 8 Bytes is sent which begins with a "P" (0x50) character. However, the proxy does not seem to forward these 8 bytes. The server then checks if the first byte is a "P". However, it is an "h" (from "hello:...") and therefore fails.